| Restocking Fee | No |
|---|---|
| Return shipping will be paid by | Seller |
| All returns accepted | Returns Accepted |
| Item must be returned within | 30 Days |
| Refund will be given as | Money Back |
| MPN | OPT-42002-0024S |
| Compatible Model | For Pentair MasterTemp & Max-D-Therm |
| Material | Stainless Steel |
| Compatible Brand | For Pentair |
| Brand | Optimum Pool Technologies, Inc. |
| Style | Stack Flue Sensor |
| Color | Silver |
| Type | Pool Heater |
Check the listing for details. Stack Flue Sensor for MasterTemp & Max-E-Therm Heaters - Replaces 42002-0024S. Color: Silver, Condition: New. Listed at 19.99 USD. Replaces Pentair/Sta-Rite 42002-0024S Typical Error Codes: E-05, E-06 These Pentair MasterTemp error codes usually mean that the stack flue sensor needs to be replaced. Location: The Indoor Stack Flue Switch (ES2) / Stack Flue Sensor (SFS) is located on the exhaust Elbow. Function: The Stack Flue Sensor prevents the flue gas output from exceeding 500 degrees F +/-18 degrees F. A stack flue sensor, located on the exhaust elbow of a pool heater, prevents the flue gas output from exceeding 500°F. When this fails, your system will show error codes E05 or E06 to indicate that the stack flue sensor must be replaced. Replacing your broken stack flue sensor is easy! Just follow these steps: 1. Turn off the filter pump and all electrical power to the pool heater. 2. Allow the heater to cool for at least 30 minutes before proceeding to the next step. 3. Unbolt and remove both the upper left and upper right jackets from the heater. 4. Disconnect the wires from the old indoor stack flue sensor. 5. Remove the old sensor by turning it counter-clockwise with a ½” open end wrench. 6. Install the new sensor, sealing it with a bead of RTV sealant before threading it into the exhaust elbow. Specifications: Manufacturer: Optimum Pool Technologies Model: OPT-42001-0053SReplaces Pentair/Sta-Rite 42002-0024S Typical Error Codes: E-05, E-06 These Pentair MasterTemp error codes usually mean that the stack flue sensor needs to be replaced. Location: The Indoor Stack Flue Switch (ES2) / Stack Flue Sensor (SFS) is located on the exhaust Elbow. Function: The Stack Flue Sensor prevents the flue gas output from exceeding 500 degrees F +/-18 degrees F. A stack flue sensor, located on the exhaust elbow of a pool heater, prevents the flue gas output from exceeding 500°F. When this fails, your system will show error codes E05 or E06 to indicate that the stack flue sensor must be replaced. Replacing your broken stack flue sensor is easy! Just follow these steps: 1. Turn off the filter pump and all electrical power to the pool heater. 2. Allow the heater to cool for at least 30 minutes before proceeding to the next step. 3. Unbolt and remove both the upper left and upper right jackets from the heater. 4. Disconnect the wires from the old indoor stack flue sensor. 5. Remove the old sensor by turning it counter-clockwise with a ½” open end wrench. 6. Install the new sensor, sealing it with a bead of RTV sealant before threading it into the exhaust elbow. Specifications: Manufacturer: Optimum Pool Technologies Model: OPT-42001-0053S