| Restocking Fee | No |
|---|---|
| Return shipping will be paid by | Buyer |
| All returns accepted | Returns Accepted |
| Item must be returned within | 30 Days |
| Refund will be given as | Money back or replacement (buyer's choice) |
| Frequency measurement range | 0.1Hz~50MHz |
| MPN | 202409031041 |
| Dimension | 260mm × 90mm × 300mm |
| Weight | 3kg |
| Brand | VTSYIQI |
| Maximum output power | 5W |
| Input Impedance | 500kΩ/30pF |
| Output waveform | sine wave |
| Load resistance | ≥8Ω |
| Display effective number of digits | five |
| Country/Region of Manufacture | China |
| Frequency stability | ± 5 × 10-5/d |
| Display mode Display range | 0.100Hz~50000kHz |
| Output Frequency | 0.1Hz~3MHz |
Check the listing for details. Laboratory Function Signal Generator Counter with DC Level Adjustment Function. Condition: New. Listed at 495.00 USD. Laboratory Function Signal Generator Counter with DC Level Adjustment Function Overview:Function signal generator / counter, with a continuous signal, swept signal, function signal, pulse signal, can output a single pulse, point frequency sinusoidal signal and a variety of output signals and external frequency measurement function, is the electronic engineers, electronic laboratories, production lines, and scientific research, teaching and the configuration of the required ideal equipment.Features :Can simultaneously display the output amplitude (3-digit LED) and output frequency (5-digit LED)Can be used as a frequency meter (50MHz and other precision)Multiple output modes: (spot frequency, FM, internal and external frequency sweep)Full-featured output protectionHigh reliability MTBF>10000 hoursDC level adjustment functionAdoption of electronic switchParameter :Maximum output power: 5W Output waveform: sine wave Load resistance: ≥8Ω Output frequency range: 0.1Hz~50kHz, f≥50kHz automatic shutdown Output Frequency 0.1Hz~3MHz Output Impedance Function, Spot Frequency Output 50Ω TTL/CMOS output 600Ω Output Signal Waveform Function Output: Sine, Triangle, Square (Symmetrical or Asymmetrical Output) TTL/CMOS Output: Pulse wave (CMOS output f≤100kHz) Frequency measurement range 0.1Hz~50MHz Input Voltage Range (Attenuation 0dB) 150mV~2V (0.1Hz~1Hz) 30mV to 2V (1Hz to 50MHz) Input Impedance 500kΩ/30pF Waveform Adaptation Sine wave, Square wave Filter cutoff frequency Approx. 100kHz (in-band attenuation to meet minimum input voltage requirements) Measurement time 0.3s (fi>3Hz) Measurement time 0.3s (fi>3Hz) Single measured signal period (fi≤3Hz) Display mode Display range: 0.100Hz~50000kHz Display effective number of digits: five Measurement Error Time base error ± Trigger error (Trigger error: If the signal-to-noise ratio of the measured signal is better than 40dB during a single cycle of measurement, the trigger error will be ≤0.3%) Time base nominal frequency: 10MHz Frequency stability: ± 5 × 10-5/d Dimension 260mm × 90mm × 300mm Weight 3kg