| Return shipping will be paid by | Seller |
|---|---|
| All returns accepted | Returns Accepted |
| Item must be returned within | 30 Days |
| Refund will be given as | Money Back |
| Brand | Napco Security Systems |
| MPN | GEM-P9600 |
| Shipping Profile ID | 54619861020 |
| Type | Security System Controller |
| Model | GEM-P9600 |
| Compatible Brand | Napco Security |
| Connectivity | N/A |
| Color | N/A |
Check the listing for details. Napco Gemini P9600 Security Panel, 8-96 Zones (GEM-P9600). Color: N/A, Condition: New. Listed at 399.99 USD. The Napco Gemini P9600 Security Panel, 8-96 Zones is a fierce, multi-tasking hybrid security control panel suitable for high-end security applications and home automation integration. This microcomputer-based burglary and residential fire alarm control panel supports 96 users, four RF receivers, two interior bypass groups, automatic system arming/disarming, and three relay outputs (expandable to 96).Allows permanent panel connection to home automation hubsOffers up to eight independent area partitionsSupports up to 96 users, 15 keypads, and 800 logged eventsCompatible with GEM-ACCESS access control The P9600 panel offers 8 to 96 hardwired or wireless zones/points, with up to 48 RF wireless points, including eight 2-wire fire zones. Among its advanced features, the P9600 offers support for permanent panel-port connection to automation hubs using the GEM-RS232 interface. The panel also offers programmable partitioning, allowing independent control of eight separate areas. Easy Programming and Use With EZ programming, users can easily set up the system through a keypad. The panel also includes a built-in scheduler that allows you to program up to 255 scheduled events. Its exclusive V.A.L.I.D. feature (Verifying Automatic Line Integrity Diagnostic) reduces false alarms due to changes in line resistance. Additionally, the overview mode permits monitoring and control of total system from one keypad. Advanced Compatibility Features The P9600 offers an onboard programmable lug and GEM-ACCESS access control compatibility, allowing versatile use in most residential and commercial applications. It also supports GEM-automation with the alarm-to-pc automation software package interface, GEM-Developer Development Professional's Protocol for custom integration, and Phast automation systems with the GEM-PHASTPAK interface. The control panel features fuseless maintenance-free operation. It comes with the P9600 controller in an enclosure, an integral digital communicator, and a step-down transformer.Product Features Control Panel8 End-of-line-resistor burglary zones programmable for area, exit/entry delay, interior, follower, day zone, chime, fire option, sensor watch, swinger shutdown, zone anding and a variety of other featuresUp to 96 zones with optional zone-expansion modules and 4-zone keypadsIncluding up to 8 2-wire fire zonesUp to 96 individually coded users, each with a programmable authority levelExclusive RS232 panel-port supports PC home automation/ networking integration for 9600 baud comprehensive communications3 On-board relay outputs; expandable to 96Three keypad panics: fire, police and auxiliaryUp to 8 independent area partitionsUp to 8 separate access stations by up to 96 usersUp to 64 separately-addressable X-10 devices with the GEM-X10 kitEnglish-language prompts and system status messages from choice of keypad modelsUser-customized zone descriptions, reprogrammable as requiredSupports 2-wire and 4-wire smoke detectorsReports alarms, restores and troubles by zone255 Event schedule800 Event logOverview mode permits monitoring and control of total system from one keypadSupports up to 4 RF receiversGuard-tour programmable for start time, tour length, and checkpoints (tour stations)2 Programmable entry delay times2 Interior-bypass groupsDynamic battery test interrupts charging and places battery under load every four hoursChime by zone; programmable durationNon-volatile RAM retains memory during power lossesQuickloader programmableAuto-download logExclusive V.A.L.I.D. feature (verifying automatic line integrity diagnostic) reduces false alarms due to changes in line resistance CommunicatorCompatible with all major receiver formats, including BFSK, 4/2, modem 2, SIA, 4/3/1, 4 + 2 express and point IDRotary dial and touchtone with rotary backup3 20-Digit telephone numbersBackup reporting; double reporting; split reporting96 User codes with opening/closing reporting by userAC failure reporting with programmable report delaySupervised telephone line cut with programmable delayPager capabilitySIA CP01 compliant versions availableTechnical DetailsManufacturer Part #: GEM-P9600UPC: 785026020385Operating temperature: 32 to 120 degrees F (0 to 49 degrees C)Input power: 16.5VAC via class 2 plug-in 40VA transformer, suppliedLoop voltage: 10-13VACLoop current: 2.5mA with 2.2ohm end-of-line resistor (model EOL2.2K); 5mA for 2-wire smoke detector zonesLoop resistance: 300W max.; 50W for 2-wire smoke detector zonesRelay outputs (burglary; reset; aux): wet, 12VDC, 1.2A max.; Dry (cut related jumper for dry contacts), SPDT contacts 24VDC, 2A, 0:6 PFAuxiliary power output: 12VDC regulatedRemote power output: 12VDC regulated (for keypads), 750 mA combined standby current (remote power + aux. power + reset relay power)Standby time: residential fire/burglary and commercial burglary, 4 hours minimumEZM module: GEM-EZM8: input, 50mA (including PGM output) PGM output: 5mA, 12V special applicationKeypad current: GEM-RP1CAE2: 100mA; 35mA if backlighting is disabled (cut W1, W2, W3)PGM output: 5mA, 12V special